A portable power station can keep a fridge and freezer running during a power cut, provided it can cope with their starting demand. How long it lasts depends on the battery capacity and the appliances’ average energy use. In the illustrative calculation below, a fully charged 1,000Wh station supplies a combined average appliance load of 70W for about 11 hours. Your own result could be considerably different.
This guide explains how to estimate that time before you need it. The examples are calculations, not product tests or promises that a particular battery will run your appliances overnight.

Why the wattage on the label can be misleading
A fridge or freezer does not usually draw its full running power all the time. Its compressor switches on to cool the interior and switches off when the required temperature is reached. Frost-free models can also use extra energy during a defrost cycle.
A label showing 150W therefore does not necessarily mean the appliance uses 150Wh every hour. Equally, a brief low reading on a power station display does not tell you the whole day’s consumption. Room temperature, door opening, warm food, thermostat settings and the condition of door seals all affect the result.
Treat a combined fridge-freezer as one appliance. If you have a separate fridge and freezer, add their energy use together.
Measure a normal day of electricity use
A suitable plug-in energy monitor can record how many kilowatt-hours your appliance uses over 24 hours. Measure several representative days where possible, so you include compressor cycling and defrost activity. Follow the monitor’s ratings and instructions, and avoid moving a heavy appliance yourself just to reach a socket.
For example, imagine a fridge uses 0.7kWh a day and a separate freezer uses 1.0kWh. Together that is 1.7kWh, or 1,700Wh. Divide by 24 and their combined average demand is about 71W.
If you cannot measure consumption, the energy label’s annual kWh figure can give a rough starting point: multiply it by 1,000 and divide by 365, then divide by 24 to estimate average watts. The label reflects standard test conditions, so allow for your kitchen being warmer or your use being different.
Allow for the power station itself
Battery capacity is quoted in watt-hours, often written as Wh. A 2,000Wh battery stores roughly twice the nominal energy of a 1,000Wh battery. Watts describe its output capability; they do not tell you how long it will last.
Some stored energy is lost when the station converts battery power into mains electricity. Its inverter also consumes energy while the AC sockets are enabled, including when the fridge compressor is resting. That background use can make a noticeable difference over a long power cut.
For the table below, we assume 85% of nominal capacity is available after conversion losses and reserve, plus a separate 10W allowance for the station’s background consumption. These are illustrative assumptions, not specifications shared by every model. Use the manufacturer’s measured usable capacity and idle consumption if available.
Estimated hours = battery capacity in Wh × 0.85 ÷ (average appliance watts + 10). Start with a full battery; a partly charged or ageing battery will usually give less time. Your own trial is the better guide.
Illustrative fridge and freezer running times
The columns show the total average demand of all cooling appliances connected. They are example loads, not claimed averages for all UK fridges or freezers. Figures are rounded and assume no solar input or other appliances.
| Battery capacity | 40W average load | 70W average load | 100W average load |
|---|---|---|---|
| 500Wh | 8.5 hours | 5.3 hours | 3.9 hours |
| 1,000Wh | 17 hours | 10.6 hours | 7.7 hours |
| 2,000Wh | 34 hours | 21.3 hours | 15.5 hours |
How much battery would you need for a full day
Using the same assumptions, a 70W average fridge and freezer load needs about 2,260Wh of nominal battery capacity for 24 hours: (70 + 10) × 24 ÷ 0.85. A 2,000Wh station would fall short in this example, even though it might last a full day with more efficient appliances.
Leave headroom for warmer weather and unexpected demand. Charging a phone or powering a lamp will also reduce cooling time. A kettle, air fryer or room heater can use a substantial share of the battery, so decide whether keeping food cold is your priority.
Check that the compressors will start
Enough battery capacity is only part of the job. The station needs sufficient continuous AC output for the running appliances and enough supported starting surge for their compressors. With two separate appliances, allow for their demands overlapping and check defrost heater demand too.
Check the appliance and station manuals, including the required mains supply, recommended inverter type and any restrictions on motor loads. Do not assume a boost mode intended for heating appliances is suitable for a fridge. Test the setup before relying on it.
Check automatic AC timeout and energy-saving settings. A station that turns its sockets off when the compressor pauses could leave the fridge without power when it needs to start again. Follow the appliance’s restart instructions and avoid rapid repeated switching.
Keep food cold when the power is off
Keep doors closed as much as possible. UK Food Standards Agency guidance estimates that an unpowered fridge stays cold for up to four hours, while a full freezer can keep food frozen for up to 48 hours, or 24 hours if half full. These are estimates, affected by the appliance and room temperature; they are not battery running times.
Use a fridge thermometer and normally keep the fridge at 5°C or below. Follow the linked official guidance if temperatures rise or food begins to thaw. Take extra care for people vulnerable to food poisoning, and never taste food to decide whether it is safe.
A practical plan for the next power cut
Keep the station charged according to its manual, measure your appliances and try them on battery power while mains electricity is available. Monitor both battery use and appliance temperatures. A short trial can check operation; a longer supervised trial gives a better runtime estimate.
Plug appliances into the station as instructed, keep ventilation clear and cables out of walkways. Never plug the station’s AC output into a household wall socket to supply your home’s wiring.
Solar charging can extend running time, but its contribution depends on weather, daylight, panel placement and the station’s input limits. Plan the essential cooling period without assuming reliable sunshine.
The most useful next step is to find your fridge and freezer’s combined daily kWh consumption. With that figure and a checked starting-power requirement, you can choose a battery capacity that fits the length of power cut you want to cover.